{"id":1756,"date":"2015-09-01T20:41:25","date_gmt":"2015-09-01T18:41:25","guid":{"rendered":"http:\/\/www.epitype.de\/?page_id=1756&#038;lang=en"},"modified":"2015-11-12T19:12:20","modified_gmt":"2015-11-12T18:12:20","slug":"faq-labs","status":"publish","type":"page","link":"https:\/\/www.epitype.de\/en\/information-for-diagnostics-laboratories\/faq-labs\/","title":{"rendered":"FAQ Labs"},"content":{"rendered":"\n<style type=\"text\/css\" data-created_by=\"avia_inline_auto\" id=\"style-css-av-av_heading-18019a48b53072d47488e67751e611c8\">\n#top .av-special-heading.av-av_heading-18019a48b53072d47488e67751e611c8{\npadding-bottom:10px;\n}\nbody .av-special-heading.av-av_heading-18019a48b53072d47488e67751e611c8 .av-special-heading-tag .heading-char{\nfont-size:25px;\n}\n.av-special-heading.av-av_heading-18019a48b53072d47488e67751e611c8 .av-subheading{\nfont-size:15px;\n}\n<\/style>\n<div  class='av-special-heading av-av_heading-18019a48b53072d47488e67751e611c8 av-special-heading-h1 blockquote modern-quote  avia-builder-el-0  el_before_av_textblock  avia-builder-el-first '><h1 class='av-special-heading-tag '  itemprop=\"headline\"  >Frequently asked questions &#8211; diagnostic laboratories<\/h1><div class=\"special-heading-border\"><div class=\"special-heading-inner-border\"><\/div><\/div><\/div>\n<section  class='av_textblock_section av-av_textblock-0366cc7376be6c9e82a3e9cc8987b64f '   itemscope=\"itemscope\" itemtype=\"https:\/\/schema.org\/CreativeWork\" ><div class='avia_textblock'  itemprop=\"text\" >            <div class=\"qae-faqs-container qae-faqs-list-container\">\n\t\t\t\t\t\t\t<ul class=\"qe-faqs-filters-container\">\n\t\t\t\t<li class=\"active\"><a class=\"qe-faqs-filter all-faqs\" href=\"#\" data-filter=\"*\">All<\/a><\/li>\n\t\t\t\t<li><a class=\"qe-faqs-filter\" href=\"#fuer-labore\" data-filter=\".fuer-labore\">For Labs<\/a><\/li>\t\t\t<\/ul>\n\t\t\t<ol class=\"qe-faqs-index-list\"><div id=\"qe-faqs-index\" class=\"qe-faqs-index\">\n\t\t\t\t\t<li class=\"for-labs\">\n\t\t\t\t\t\t<a href=\"#qaef-1643\">Which tools and equipment do I need for performing GynTect\u00ae?<\/a>\n\t\t\t\t\t<\/li>\n\n\t\t\t\t\n\t\t\t\t\t<li class=\"for-labs\">\n\t\t\t\t\t\t<a href=\"#qaef-1662\">How long does it take to get a GynTect\u00ae test result?<\/a>\n\t\t\t\t\t<\/li>\n\n\t\t\t\t\n\t\t\t\t\t<li class=\"for-labs\">\n\t\t\t\t\t\t<a href=\"#qaef-1663\">Which controls are included in a GynTect\u00ae run?<\/a>\n\t\t\t\t\t<\/li>\n\n\t\t\t\t<\/div><\/ol>\t\t<div id=\"qaef-1643\" class=\"qe-faq-list for-labs\">\n\t\t\t<div class=\"qe-list-title\">\n\t\t\t\t<h4>\n\t\t\t\t\t<i class=\"fa fa-question-circle\"><\/i> Which tools and equipment do I need for performing GynTect\u00ae?\t\t\t\t<\/h4>\n\t\t\t<\/div>\n\t\t\t<div class=\"qe-list-content\">\n\t\t\t\t<p>GynTect<sup>\u00ae<\/sup>\u00a0is a PCR-based test, during which the methylation of certain DNA regions is detected. Prior to the performance of the PCR test the patient sample is treated chemically. You receive the Bisulfite conversion kit required for this chemical treatment from the GynTect<sup>\u00ae<\/sup> distributor. For the performance of the bisulfite treatment you need a heating block with cooling option, e.g. a simple thermocycler with a block for 0.5 ml reaction tubes.\u00a0The\u00a0GynTect<sup>\u00ae\u00a0<\/sup>assay currently is established on the realtime-PCR platforms Abi7300 and Abi7500 (Life Technologies).<\/p>\n<br \/><a class=\"qe-faq-top\" href=\"#qe-faqs-index\"><i class=\"fa fa-angle-up\"><\/i> Back to Index<\/a>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div id=\"qaef-1662\" class=\"qe-faq-list for-labs\">\n\t\t\t<div class=\"qe-list-title\">\n\t\t\t\t<h4>\n\t\t\t\t\t<i class=\"fa fa-question-circle\"><\/i> How long does it take to get a GynTect\u00ae test result?\t\t\t\t<\/h4>\n\t\t\t<\/div>\n\t\t\t<div class=\"qe-list-content\">\n\t\t\t\t<p>&nbsp;<\/p>\n<p>GynTect<sup>\u00ae<\/sup>\u00a0can be performed within one lab working day, independent of the number of tests performed in parallel. The hands-on time, which includes sample preparation (10 min) prior to the bisulfite treatment and a purification (30 min) after this chemical treatment, as well as the\u00a0set-up of the PCR reaction (10 &#8211; 30 min depending upon the number of samples), is readily comprehensible. At the end of the PCR run max. 30 min are required for the evaluation of the results.<\/p>\n<br \/><a class=\"qe-faq-top\" href=\"#qe-faqs-index\"><i class=\"fa fa-angle-up\"><\/i> Back to Index<\/a>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div id=\"qaef-1663\" class=\"qe-faq-list for-labs\">\n\t\t\t<div class=\"qe-list-title\">\n\t\t\t\t<h4>\n\t\t\t\t\t<i class=\"fa fa-question-circle\"><\/i> Which controls are included in a GynTect\u00ae run?\t\t\t\t<\/h4>\n\t\t\t<\/div>\n\t\t\t<div class=\"qe-list-content\">\n\t\t\t\t<p>A\u00a0GynTect<sup>\u00ae\u00a0<\/sup>assay for a patient sample includes two internal controls: (1) the detection of a DNA fragment which only functions if the sample material after bisulfite treatment is\u00a0of sufficient quality and quantity; this fragment does not contain methylated bases; (2) the detection of a methylated\u00a0DNA fragment which indicates that the methylation of the DNA has remained stable during sample transport and preparation.<\/p>\n<br \/><a class=\"qe-faq-top\" href=\"#qe-faqs-index\"><i class=\"fa fa-angle-up\"><\/i> Back to Index<\/a>\t\t\t<\/div>\n\t\t<\/div>\n\t\t            <\/div>\n\t\t\n<\/div><\/section>\n","protected":false},"excerpt":{"rendered":"","protected":false},"author":10,"featured_media":0,"parent":1706,"menu_order":4,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"class_list":["post-1756","page","type-page","status-publish","hentry"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>FAQ Labs - Epitype GmbH<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.epitype.de\/en\/information-for-diagnostics-laboratories\/faq-labs\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"FAQ Labs - Epitype GmbH\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.epitype.de\/en\/information-for-diagnostics-laboratories\/faq-labs\/\" \/>\n<meta property=\"og:site_name\" content=\"Epitype GmbH\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/oncgnostics\/\" \/>\n<meta property=\"article:modified_time\" content=\"2015-11-12T18:12:20+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.epitype.de\/wp-content\/uploads\/2015\/03\/oncgnostics-logo2.png\" \/>\n\t<meta property=\"og:image:width\" content=\"340\" \/>\n\t<meta property=\"og:image:height\" content=\"156\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.epitype.de\\\/en\\\/information-for-diagnostics-laboratories\\\/faq-labs\\\/\",\"url\":\"https:\\\/\\\/www.epitype.de\\\/en\\\/information-for-diagnostics-laboratories\\\/faq-labs\\\/\",\"name\":\"FAQ Labs - Epitype GmbH\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.epitype.de\\\/en\\\/#website\"},\"datePublished\":\"2015-09-01T18:41:25+00:00\",\"dateModified\":\"2015-11-12T18:12:20+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.epitype.de\\\/en\\\/information-for-diagnostics-laboratories\\\/faq-labs\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.epitype.de\\\/en\\\/information-for-diagnostics-laboratories\\\/faq-labs\\\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.epitype.de\\\/en\\\/information-for-diagnostics-laboratories\\\/faq-labs\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Startseite\",\"item\":\"https:\\\/\\\/www.epitype.de\\\/en\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Information for diagnostic laboratories\",\"item\":\"https:\\\/\\\/www.epitype.de\\\/en\\\/information-for-diagnostics-laboratories\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"FAQ Labs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.epitype.de\\\/en\\\/#website\",\"url\":\"https:\\\/\\\/www.epitype.de\\\/en\\\/\",\"name\":\"epitype GmbH\",\"description\":\"Molecular cancer diagnostics\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.epitype.de\\\/en\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"FAQ Labs - Epitype GmbH","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.epitype.de\/en\/information-for-diagnostics-laboratories\/faq-labs\/","og_locale":"en_US","og_type":"article","og_title":"FAQ Labs - Epitype GmbH","og_url":"https:\/\/www.epitype.de\/en\/information-for-diagnostics-laboratories\/faq-labs\/","og_site_name":"Epitype GmbH","article_publisher":"https:\/\/www.facebook.com\/oncgnostics\/","article_modified_time":"2015-11-12T18:12:20+00:00","og_image":[{"width":340,"height":156,"url":"https:\/\/www.epitype.de\/wp-content\/uploads\/2015\/03\/oncgnostics-logo2.png","type":"image\/png"}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.epitype.de\/en\/information-for-diagnostics-laboratories\/faq-labs\/","url":"https:\/\/www.epitype.de\/en\/information-for-diagnostics-laboratories\/faq-labs\/","name":"FAQ Labs - Epitype GmbH","isPartOf":{"@id":"https:\/\/www.epitype.de\/en\/#website"},"datePublished":"2015-09-01T18:41:25+00:00","dateModified":"2015-11-12T18:12:20+00:00","breadcrumb":{"@id":"https:\/\/www.epitype.de\/en\/information-for-diagnostics-laboratories\/faq-labs\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.epitype.de\/en\/information-for-diagnostics-laboratories\/faq-labs\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.epitype.de\/en\/information-for-diagnostics-laboratories\/faq-labs\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Startseite","item":"https:\/\/www.epitype.de\/en\/"},{"@type":"ListItem","position":2,"name":"Information for diagnostic laboratories","item":"https:\/\/www.epitype.de\/en\/information-for-diagnostics-laboratories\/"},{"@type":"ListItem","position":3,"name":"FAQ Labs"}]},{"@type":"WebSite","@id":"https:\/\/www.epitype.de\/en\/#website","url":"https:\/\/www.epitype.de\/en\/","name":"epitype GmbH","description":"Molecular cancer diagnostics","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.epitype.de\/en\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"_links":{"self":[{"href":"https:\/\/www.epitype.de\/en\/wp-json\/wp\/v2\/pages\/1756","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.epitype.de\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/www.epitype.de\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/www.epitype.de\/en\/wp-json\/wp\/v2\/users\/10"}],"replies":[{"embeddable":true,"href":"https:\/\/www.epitype.de\/en\/wp-json\/wp\/v2\/comments?post=1756"}],"version-history":[{"count":1,"href":"https:\/\/www.epitype.de\/en\/wp-json\/wp\/v2\/pages\/1756\/revisions"}],"predecessor-version":[{"id":9622,"href":"https:\/\/www.epitype.de\/en\/wp-json\/wp\/v2\/pages\/1756\/revisions\/9622"}],"up":[{"embeddable":true,"href":"https:\/\/www.epitype.de\/en\/wp-json\/wp\/v2\/pages\/1706"}],"wp:attachment":[{"href":"https:\/\/www.epitype.de\/en\/wp-json\/wp\/v2\/media?parent=1756"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}